Firmware

Language
Supported character sets
Supported fonts
ROM-based plots

Environment

These specifications are for the cutter without substrate.
Operating temperature
Storage temperature
Relative humidity
TIP:
The use of dimensionally stable substrate is an essential pre-requisite to obtain high cut quality.
Additionally, substrate expansion or contraction may occur as a result of temperature variations. To improve the
dimensional stability of substrate, let it stabilize to the current environmental conditions before use, for a
minimum period of 24 hours.

Electrical

The power entry module detects the line voltage and switches automatically between 100 V and 240 V.
Input voltage
Input frequency
Maximum load current
Power consumption
Fuses
WARNING!
For continued protection against risk of fire, replace fuses only with the same type and rating of
fuse.
ENWW
DM/PL, HP-GL (758x emulation), HP-GL/2
Standard ASCII
Sans serif (single stroke and medium)
Confidence plot, DIN plot
15 to 35°C (59 to 95°F)
−30 to 70°C (−22 to 158°F)
35 to 75%, non-condensing
100–120/200–240 V ±10%
50/60 Hz
2 A
85 VA
T2.0A 250V