Technical Data - Siemens SINAMICS S120 Combi User Manual

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

7.8

Technical data

Table 7- 9
Technical data Single Motor Modules Booksize Compact (3 A to 18 A)
Single Motor Modules Booksize Compact
Output current
Rated current (I
)
n
Base-load current (I
)
H
Intermittent duty current (I
Peak current (I
)
max
Output voltage
DC link current I
d
DC link voltage
(up to 2000 m above sea level)
DC link capacitance
Overvoltage tripping
Undervoltage tripping
1)
Electronics power supply
Electronics current consumption at 24 V DC
Current carrying capacity
DC link busbar
Reinforced DC link busbars
24 V busbar
Max. current motor brake
Unit rating
Based on I
(600 V
; 4 kHz)
n
DC
Based on I
H
Total power loss
(including electronics losses)
Max. pulse frequency
Without derating
With derating
Max. ambient temperature
Without derating
With derating
Sound pressure level
Cooling method
Cooling air requirement
Weight
1) Default for 400 V line supplies; undervoltage trip threshold can be reduced by a maximum of 80 V and is adjusted to the
parameterized line voltage.
2) For an overview, see the power loss tables in chapter Control cabinet installation
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
6SL3420–
A
ACrms
A
) 40%
A
s6
ACrms
A
ACrms
V
ACrms
A
DC
V
DC
μF
V
DC
V
DC
V
DC
A
DC
A
DC
A
DC
A
DC
A
kW
kW
W
2)
kHz
kHz
°C
°C
dB(A)
m
/h
3
kg
Motor Modules Booksize Compact as expansion axes
1TE13-0AAx
1TE15-0AAx
3
5
2.6
4.3
3.5
6
9
15
0 - 0.717 x DC link voltage
3.6
6
510 – 720
110
110
820 ± 2 %
380 ± 2 %
24 (20.4 - 28.8)
0.85
0.85
100
100
150
150
20
20
2
2
1.6
2.7
1.4
2.3
68
98
at 8 kHz
at 8 kHz
8
8
16
16
40
55
<60
<60
Internal air
cooling
29.6
29.6
2.7
2.7
7.8 Technical data
1TE21–0AAx
1TE21–8AAx
9
18
7.7
15.3
10
24
27
54
11
22
110
235
0.85
0.85
100
100
150
150
20
20
2
2
4.8
9.7
4.1
13.7
100.4
185.4
at 4 kHz
at 4 kHz
4
4
16
16
<60
<60
29.6
29.6
2.7
3.4
133

Advertisement

Table of Contents
loading

Table of Contents