Siemens SINAMICS S120 Combi User Manual page 251

Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Table 13- 7
Comparison between MOTION-CONNECT 500 and MOTION-CONNECT 800PLUS DRIVE-CLiQ cables
DRIVE-CLiQ signal cable
Approvals
VDE
cURus or UR/CSA
UR-CSA File No.
1)
in conformance with RoHS
Rated voltage V
/V
0
in accordance with EN 50395
Test voltage, rms
Operating temperature at the surface
Permanently installed
Moveable
Tensile load, max.
Permanently installed
Moveable
Smallest bending radius
Permanently installed
Moveable
Torsional stress
Bending operations
Max. traversing speed
Max. acceleration
insulation material
Oil resistance
Protective jacket
Flame retardant
1) The file number is printed on the cable jacket.
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
MOTION-CONNECT 500
Yes
UL STYLE 2502/CSA-N.210.2-M90
Yes
Yes
30 V
500 V
-20 to +80°C
0 to 60°C
80 N/mm
2
30 N/mm
2
35 mm
125 mm
30°/m absolute
100000
30 m/min
2 m/s
2
CFC/silicone-free
EN 60811-2-1
(mineral oil only)
PVC
EN 60332-1-1 to 1-3
Cabinet design and EMC
13.7 Connection system
MOTION-CONNECT 800PLUS
Yes
UL STYLE 2502/CSA-N.210.2-M90
Yes
Yes
30 V
500 V
-20 to +80°C
-20 to +60°C
50 N/mm
2
20 N/mm
2
35 mm
75 mm
30°/m absolute
10 million
300 m/min
Up to 50 m/s
(3 m)
2
CFC/halogen-free/silicon-free
EN 60811-2-1
PUR, HD22.10 S2
(VDE 0282, Part 10)
EN 60332-1-1 to 1-3
249