Additional system components
10.2 DRIVE-CLiQ Hub Module DMC20
10.2.3.2

X524 Electronics power supply

Table 10- 16 Terminals for the electronics power supply
Terminal
+
+
M
M
Max. connectable cross-section: 2.5 mm
Type: Screw terminal 3 (see Chapter "Control cabinet installation and EMC / connection system")
Note
The two "+" and "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
The current consumption increases by the value for the DRIVE-CLiQ participants.
10.2.3.3

X500 - X505 DRIVE-CLiQ interfaces

Table 10- 17 X500-X505 DRIVE-CLiQ interfaces
Pin
1
2
3
4
5
6
7
8
A
B
Connector type
RJ45 socket
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 pieces) Order number: 6SL3066-4CA00-0AA0
194
Designation
Electronics power supply
Electronics power supply
Electronics ground
Electronics ground
2
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Technical specifications
Voltage: 24 V DC (20.4 V – 28.8 V)
Current consumption: Max. 0.5 A
Max. current via jumper in connector: 20 A
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3