Panasonic KX-UDS124 Installation Manual page 35

Dect 6.0 cell station unit (sip)
Hide thumbs Also See for KX-UDS124:
Table of Contents

Advertisement

3.
Once SIP-CS(1) turns on, release the RESET switch, and then press the RESET switch again.
SIP-CS(1) will enter Site Survey Master mode.
4.
Turn on SIP-CS(2) normally. SIP-CS(2) will enter Site Survey Slave mode automatically when it receives
a signal from SIP-CS(1).
5.
Place SIP-CS(1) where the Air Sync Master CS is planned to be located.
LED:
Red and green alternate flashing
6.
Place SIP-CS(2) in the location planned for the SIP-CS closest to the Air Sync Master CS (currently
SIP-CS[1]).
7.
Confirm whether the LED of SIP-CS(2) is green.
If it is not green, move SIP-CS(2) around to find a location where its LED turns green.
Note
The LED indicates radio signal strength levels for air synchronisation. For details, refer to "CS
Coverage Area for Establishing Conversations" in "4.2 Site Planning".
SIP-CS(1)
AC
(Site Survey
adaptor
Master Mode)
Planned Location for
Air Sync Master CS
LED:
Red flashing
SIP-CS(2)
(Site Survey
Slave Mode)
AC
adaptor
SIP-CS(1)
AC
adaptor
4 Deployment Procedure
Planned Location:
Installation Guide
35

Hide quick links:

Advertisement

Table of Contents
loading