5 DATA USED FOR POSITIONING CONTROL
Storage item
Md.28
Axis feedrate
Md.29
Speed-position switching
control positioning amount
Md.30
External input signal
The speed which is actually output as a command at that time in each axis is
stored. (May be different from the actual motor speed)
"0" is stored when the axis is at a stop.
Update timing: 56.8ms
POINT
Md.22
Refer to
Feedrate
The value set as the movement amount for the position control to end after
changing to position control with the speed-position switching control (INC mode)
is stored.
The ON/OFF state of the external input/output signal is stored.
The following items are stored.
Upper limit signal
Lower limit signal
Stop signal
External command signal/switching signal
Near-point dog signal
5 - 124
Storage details