Configuring generator operation in the drive

The generator mode for the drive-integrated ESR is configured using the following drive
parameters:
Parameter
Description
p0888
ESR: Configuration
Value
3
Parameter
Description
p1240
Vdc controller or Vdc monitoring configuration
Value
2
Parameter
p1248
p1244
p1248
r0208
T1
T2
Figure 6-6
Note
Generator operation can be restricted to just the ESR function using drive parameter p1259.
Special Functions
Function Manual, 09/2011, 6FC5397-2BP40-2BA0
Meaning
Generator operation (Vdc controller)
Meaning
When reaching the lower DC link voltage threshold (p1248) – for ESR – the
motor is braked in order to utilize its kinetic energy to buffer the DC link.
Description
Lower DC link voltage threshold
Setting the lower threshold for the DC link voltage. For p1240 = 2, this threshold is
used as setpoint limit for the Vdc_min controller.
Upper DC link voltage threshold
Lower DC link voltage threshold
Rated power unit line supply voltage.
The pulses are canceled if the DC link voltage drops below 0.9*r0208
Instant in time at which generator operation was triggered
Instant in time at which generator operation was exited
Configuring_drive_integrated_generator_operation
R3: Extended stop and retract
6.3 ESR executed autonomously in the drive