Table 36. Warning events (continued)
Event Code
Message Text and Description
4014
Library test failed due to a Drive issue.
4015
Power supply failed. Redundancy is not
available.
4016
Back up configuration data to base module
failed.
4017
Restore configuration data from Chassis
failed.
4018
Firmware upgrade failed, tape drive
reported an error while the firmware file
was applied.
4019
Drive Firmware bundle upgrade failed.
4020
Database was reset due to a problem that
prevented the library from powering up.
4021
Drive was hot-removed while in active
status as data transfer device.
4025
Library test failed due to a cartridge error.
4028
Library Test failed due to incompatible
media.
4029
Library Test failed - Cartridge bar code
indicates incompatibility with drive.
4030
Move cartridge operation failed due to
media error.
4041
Library Verify failed because the power
supply redundancy test failed.
4044
One of the Library tests failed because a
source element or destination element is not
accessible.
4059
Drive configuration failed because it does
not support encryption.
88
Dell EMC ML3 Tape Library: User's Guide
Details and Solution
v Verify the test parameters, and retry the test.
v If the test fails, check the library event log for
specific events that are associated with this
drive.
v Use the Management GUI to pull a drive
support ticket and check the device analysis
section for help.
Ensure that all power supplies are installed
properly (two per module), and that each power
supply is connected to a valid power source.
Attempt to save the library configuration, power
cycle the library, and retry the operation.
Attempt to save the library configuration, power
cycle the library, and retry the operation.
Verify that the firmware file is correct for the
drives, ensure that the drives are in a healthy
state with no cartridge in the drive, then retry
the operation.
Verify that the firmware file is correct for the
drives, ensure that the drives are in a healthy
state with no cartridge in the drive, then retry
the operation.
v If the library was restored to default settings,
restore a saved configuration by using a
previously saved config file.
v If no config file exists, then proceed in
configuring the library.
v Put the drive back into the library.
v Follow the "Removing a tape drive" on page
108 procedure to remove the tape drive.
Remove the cartridge and inspect it for damage.
Retry operation with another cartridge.
Check LTO generation for media and drives.
Remove cartridges that are not compatible to
your tape drives.
Check if Media bar code label is matching LTO
generation. Replace the label or remove
incompatible media from your system.
Remove the cartridge and inspect it for damage.
Retry operation with another cartridge.
Ensure that all power supplies are installed
properly (two per module), and that each power
supply is connected to a valid power source.
Verify the source and destination elements and
retry the move operation.
Replace drive by a model of LTO generation 4 or
higher or disable encryption for this logical
library.