6
PARAMETER SETTING
(b) DP V1/V2 Slave Parameters window
Item
DP V1 Support enable
'Fail Safe' function
enable
Slave-specific check of
cfg_data
The following window opens when the DP-Slave supports the PROFIBUS-DPV1/
V2 function.
• Start procedure
Click the
button in the "Slave Settings" window until the "DP V1/V2
Next
Slave Parameters" window will open.
• Setting items
Figure 6.7 DP V1/V2 Slave Parameters window
Table6.7 DP V1/V2 Slave Parameters Setting Items
Check this checkbox to use the PROFIBUS-DPV1 functions.
This setting is available when the DP-Slave supports the PROFIBUS-DPV1 functions.
Not checked: Not use the PROFIBUS-DPV1 functions
Checked: Use the PROFIBUS-DPV1 functions
Check this checkbox to place the DP-Slave into the 'Fail Safe' status when the DP-Master sends a clear
request.
This setting is available when the DP-Slave supports this function.
This item is fixed to be selected depending on the DP-Slave status.
For the 'Fail Safe' setting, refer to the manual for the DP-Slave.
Not checked: Not placed into 'Fail Safe' status
Checked: Placed into 'Fail Safe' status
Check this checkbox when the parameter check method for the DP-Slave is different from that of the
PROFIBUS standard.
This setting is available when the DP-Slave supports this function.
For the parameter check method, refer to the manual for the DP-Slave.
Not checked: Checks parameters based on the PROFIBUS standard
Checked: Checks parameters by the DP-Slave-specific method.
6.5 Slave Parameters
Description
1
2
3
4
5
6
7
8
(To the next page)
6
- 12