Detailed Description of Maintenance-mode Functions

1.4.1 EEPROM Parameter Initialization (Maintenance mode 01, 91)

<Function>
This function initializes the parameters, user switches and worker switches settings
registered in the EEPROM, to the initial values. Entering Maintenance mode 01 initializes
almost all of the EEPROM areas. Entering Maintenance mode 91 does not initialize some
areas, as listed below.
Data item
Maintenance-mode functions
User switches
Firmware switches
Remote activation code
Assurance mode switch settings
Activity report
Station ID data
Outside line number
Telephone function registration
Speed dialing
Group dialing
Memory contents
EEPROM customizing code (4-digit)
<Operating Procedure>
(1) Enter [0] and [1] in this order in the initial stage of the maintenance mode. (Or enter [9]
and [1] according to your need.) "SELECT 01?" (or "SELECT 91?") appears on the
LCD.
(2) Press the [Mono Start].
"PARAMETER INIT" appears on the LCD.
(3) Upon completion of parameter initialization, the machine returns to the initial stage of
the maintenance mode.
Maintenance code
Note that the first digit of the 4-digit code will be initialized
to "0". If the code is 1001, for example, it will be initialized
to "0001".
01
All of these will be
initialized.
These will not be initialized.
5-6
91
These will be initialized.
These will not be
initialized.