■ Error Code 42
Unable to print 42
Head voltage does not turn OFF.
<User Check>
- This may occur when the surrounding temperature is low. Increase the surrounding
temperature before use.
Step
1
Head flat cable connection
failure
2
Carriage flat cable connection
failure
3
Carriage PCB defective
4
Head defective
5
Power supply PCB defective
6
Main PCB defective
■ Error Code 43
Unable to print 43
Head thermistor problem
When the power was turned on, the head thermistor detected a temperature of -20
degrees centigrade or lower, or 80 degrees centigrade or higher.
Step
1
Carriage flat cable connection
failure
2
Carriage PCB defective
3
Head defective
4
Main PCB defective
Cause
Reconnect the Head flat cable.
Reconnect the Carriage flat cable.
Replace the Carriage PCB ASSY.
Replace the Head/carriage unit.
Replace the Power supply PCB ASSY.
Replace the Main PCB ASSY.
Cause
Reconnect the Carriage flat cable.
Replace the Carriage PCB ASSY.
Replace the Head/carriage unit.
Replace the Main PCB ASSY.