8.6.6

Installation via (optional) mounting brackets

With the mounting brackets available the transmitter can be
mounted in different positions.
1
4
Fig. 14: Detail view of the mounting bracket, B2, for pipe and wall
installation.
1 Washers and nuts for fastening the U-bolt |
2 Mounting screws for the transmitter |
3 U-bolt | 4 Mounting bracket
2
1
Fig. 15: Detail view of the mounting bracket, B5
1 Washers and nuts for fastening the U-bolt |
2 Mounting bracket in flange design, B5 |
3 Mounting screws for the transmitter |
4 U-bolt
24 OI/266CXX/266JXX/HART-EN Rev. B | 266CRx, 266JRx, 266CSx, 266JSx
2
3
M10798
3
4
M10800
8.7

Rotating the transmitter housing

To improve access to electrical connections and for better
visibility of the optional LCD display in the field, the transmitter
housing can be rotated through 360°. A stop prevents the
housing from being turned too far.
In order to rotate the housing, the fixing screw must be
loosened and unscrewed approx. one revolution (do not
remove it). As soon as the desired position is reached, the
fixing screw will be retightened.
Fig. 16: Rotating housing