Specifications; Operating Limits 266Crx/Jrx; Pressure Limits; Temperature Limits °C (°F) - ABB 2600T Series Operating Instruction

Multivariable pressure transmitters
Hide thumbs Also See for 2600T Series:
Table of Contents

Advertisement

14 Specifications

14.1 Operating limits 266CRx/JRx

SEE ALSO DATA SHEET DS/S26 FOR INFORMATION ON
OTHER POSSIBLE RESTRICTIONS BASED ON DIAPHRAGM
SEAL VERSIONS.

14.1.1 Pressure limits

Gauge pressure limits
The transmitter models 266CRX/JRX can operate without
damage within the following overpressure limits:
Sensors
Filling fluid
C to R
Silicone oil
C to R
Fluorocarbon
(Galden)
Static pressure limits
The transmitter models 266CRX/JRX can operate within the
specifications with the following overpressure limits:
Sensors
Filling fluid
C to R
Silicone oil
C to R
Carbon fluoride
(Galden)
The overpressure limits and upper static pressure limits can be
lowered by means of the nominal pressure rating of the
diaphragm seal flange; see remote seal data sheet
DS/S26.seal
Test pressure
The transmitters can withstand a pressure test with the
following line pressure without leaking:
Model
266CRX / JRX
1) or double the value of the pressure sensor flange pressure stage, depending on
which value is less. Meets hydrostatic test requirements of ANSI/ISA-S 82.03.
Gauge pressure limits
0.07 kPa abs., 0.7 mbar abs.,
0.5 mm Hg
and 2 MPa, 20 bar, 290 psi
or 10 MPa, 100 bar, 1450 psi
or 41 MPa, 410 bar, 5,945 psi
depending on code variant selected
17.5 kPa abs., 175 mbar abs.,
131 mmHg
and 2 MPa, 20 bar, 290 psi
or 10 MPa, 100 bar, 1450 psi
or 41 MPa, 410 bar, 5,945 psi
depending on code variant selected
Static pressure limits
3.5 kPa abs., 35 mbar abs., 0.5 psia
and 2 MPa, 20 bar, 290 psi
or 10 MPa, 100 bar, 1450 psi
or 41 MPa, 410 bar, 5,945 psi
depending on code variant selected
17.5 kPa abs., 175 mbar abs.,
2.5 psia
and 2 MPa, 20 bar, 290 psi
or 10 MPa, 100 bar, 1450 psi
or 41 MPa, 410 bar, 5,945 psi
depending on code variant selected
Test pressure
1.5 x nominal pressure (static
pressure limit) simultaneously on
both sides
1)
14.1.2 Temperature limits °C (°F)
Environment
This is the operating temperature.
All models
Silicone oil
Fluorocarbon (Galden)
All models
1)
Integral LCD display
Viton gasket
PTFE gasket
1) If may no longer be possible to read the LCD display clearly below -20 °C (-4
°F) and above 70 °C (158 °F).
IMPORTANT (NOTICE)
For applications in potentially explosive environments, the
temperature range specified on the certificate / approval which
depends upon the type of protection sought shall apply.
Process
All models
Silicone oil
Fluorocarbon (Galden)
Viton gasket
PTFE gasket
1) 85 °C (185 °F) for applications under 10 kPa, 100 mbar abs., 1.45 psia up to
3.5 kPa abs., 35 mbar abs., 0.5 psia
2) 85 °C (185 °F) for applications below atmospheric pressure up to
17.5 kPa abs., 175 mbar abs., 2.5 psia
266CRx, 266JRx, 266CSx, 266JSx | OI/266CXX/266JXX/HART-EN Rev. B 73
Ambient temperature limits
-40 and 85 °C (-40 and 185 °F)
-40 and 85 °C (-40 and 185 °F)
Ambient temperature limits
-40 and 85 °C (-40 and 185 °F)
-20 and 85 °C (-4 and 185 °F)
-20 and 85 °C (-4 and 185 °F)
Process temperature limits
-40 and 121 °C (-40 and 250 °F)
-40 and 121 °C (-40 and 250 °F)
-20 and 121 °C (-4 and 250 °F)
-20 and 85 °C (-4 and 185 °F)
1)
2)

Advertisement

Table of Contents
loading

Table of Contents