Measurement - Siemens SINAMICS S120 System Manual

Hydraulic drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

4.17.4

Measurement

When the dialog opens, the characteristic set in the drive is displayed first. After a
measurement, the measured characteristic and the characteristic set in the drive are
displayed.
Figure 4-28
Characteristic: Measurement
Requirement for the characteristic measurement
One of the following requirements must be satisfied before starting the measurement:
● All calibrations have been performed manually in the "Calibration" dialog.
● The setting "Characteristics measurement with identification" has been selected under
"Measurement" in the "Valve characteristics measurement" dialog. The calibrations are
performed automatically with this setting.
If you start the measurement without a previous calibration, a corresponding prompt is
displayed. The axis must be in the referenced state for both calibration types. If this condition
is not satisfied, a prompt appears.
Hydraulic Drive
System Manual, 04/2015, 6SL3097-4BA00-0BP1
Commissioning
4.17 Editing the valve characteristic
87