Hardware
6.2 Interfaces
6.2.2

X224 electronics power supply

Table 6- 3
X224: Electronics power supply
Terminal
+
+
M
M
Max. connectable cross-section: 2.5 mm
Type: Screw terminal
Note
Maximum cable lengths
The maximum permissible cable length is 10 m.
NOTICE
Damage caused by excessively high input voltage at the electronics power supply
A voltage connected to the electronics power supply that is above the specified upper limit
(28.8 V) can shorten the service life of the connected components. The internal fuses will
rupture for a voltage > 35 V. The internal fuses cannot be replaced.
• Only connect the specified voltages between 20.4 ... 28.8 V to the electronics power
Note
The two "+" or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
Note
Tighten the terminal strip using a screwdriver.
204
Designation
Electronics power supply
Electronics power supply
Electronics ground
Electronics ground
2
supply.
Technical data
Voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption
With 2 DRIVE-CLiQ encoders: max. 1.1 A
With 2 SSI encoders: max. 0.9 A
With 2 TTL encoders: max. 0.5 A
(without the other encoder)
Max. current via jumper in connector: 20 A (15 A ac-
cording to UL/CSA)
System Manual, 04/2015, 6SL3097-4BA00-0BP1