04.07
22910
MD number
Default setting: 0
Changes effective after POWER ON
Data type: BOOLEAN
Meaning:
22914
MD number
Default setting: 0
Changes effective after POWER ON
Datentype: BOOLEAN
Meaning:
22920
SD number
Default setting: FALSE
Changes effective after POWER ON
Datentype: BOOLEAN
Meaning:
© SIEMENS AG 2007 All rights reserved
SINUMERIK 802D sl/840D sl840D/840Di sl/840Di/810D ISO Turning - - 04.07 Edition
WEIGHTING_FACTOR_FOR_SCALE
Input unit for scaling factor
Minimum input limit: 0
Protection level: 2/7
This machine data applies in combination with external programming languages. It is active
with $MN_MM_EXTERN_LANGUAGE = 1.
It defines the unit for the scale factor P and the axial scale factors I, J, K
Meaning:
0: Scale factor in 0.001
1: Scale factor in 0.00001
AXES_SCALE_ENABLE
Enable axial scaling (G51)
Minimum input limit: 0
Protection level: 2/7
This MD enables axial scaling.
Meaning:
0: Axial scaling not possible
1: Axial scaling possible, (MD DEFAULT_SCALE_FACTOR_AXIS becomes effective)
EXTERN_FIXED_FEEDRATE_F1_ON
Activation of fixed feedrates
Minimum input limit:
Protection level: 2/7
FALSE: feedrate values stored in setting data $SC_FEEDRATE_F1_9[ ] cannot be
activated by F1 - - F9.
TRUE When programming F1 - - F9, the feedrate values stored in setting data
$SC_FEEDRATE_F1_9[ ] become effective. F0 activates rapid traverse.
Machine and Setting Data
D.2 Channel-specific machine data
Maximum input limit: 1
Unit: - -
Applies with effect from SW version: 5.2
Maximum input limit: 1
Unit: - -
gültig ab SW- -Stand: 5.2
Maximum input limit:
Unit:
Applies with effect from SW version: 6.2
D-217