HUAWEI MU609 HSPA LGA Module
Hardware Guide
Figure 3-2 Recommended power circuit of MU609 module
When the system power restarts, a discharge circuit is recommended to make sure
the power voltage drops below 1.9 V for 1s at least.

3.3.3 Output Power Supply Interface

Output power supply interface is VCC_EXT1.
Through the output power supply interface, the MU609 module can supply 1.8 V
power externally with an output current of 10 mA (typical value) for external level
conversion or other applications.
If the MU609 module is in sleep mode, the output power supply interface is in the low
power consumption state (< 500 μA). If the MU609 module is in power down mode,
the output power supply is in the disabled state.

3.4 Signal Control Interface

3.4.1 Overview

The signal control part of the interface in the MU609 module consists of the following:
Table 3-3 lists the pins on the signal control interface.
Table 3-3 Definitions of the pins on the signal control interface
Pin
Pin Name
No.
81
POWER_O
Issue 04 (2016-12-12)
Power-on/off (POWER_ON_OFF) pin
System reset (RESIN_N) pin
WAKEUP_IN Signal (WAKEUP_IN) pin
WAKEUP_OUT Signal (WAKEUP_OUT) pin
SLEEP_STATUS Signal (SLEEP_STATUS) pin
LED signal (LED_MODE) pin
Pad
Description
Type
I
Pin for controlling power-on and
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description of the Application Interfaces
Min.
Parameter
(V)
V
1.2
IH
Typ.
Max.
(V)
(V)
1.8
2.1
25