8 Troubleshooting

8. Troubleshooting
Check this section before concluding that your system is out of order.

8.1 A Listing of Errors

 An error number contains information as listed below 
OOOO 
Error No.
Error message
Cause
H.8500
Solution
Error message
Cause
H.8501
Solution
Error message
H.8502*
Cause
Solution
Error message
H.8503*
Cause
Solution
Error message
H.8504
Cause
Solution
Error message
H.8505
Cause
Solution
Error message
H.8506
Cause
Solution
Error message
H.8507
Cause
Solution
A Listing of Errors 8- 40
An error marked with an asterisk  requires a power reset.
·
Take a corrective action which is stated in the "Solutions" section of the table below.
The type of error is indicated by a 4-digit number.
·
Errors are sorted into three classifications:
·
H: High-level error ·········· Servo mechanism is shut down.
L: Low-level error ············ Operation is suspended.
C: Caution ····················· Operation continues.
Table 8-1 A Listing of PERFIBUS-related Errors
PROFIBUS Initial error
An error was detected in the hardware. The hardware may be at fault.
Replace the 2D-TZ577 Card.
When replacing the card, contact its manufacturer for advice.
PROFIBUS watch dog timer error
An error was detected in the hardware. The hardware may be at fault.
Replace the 2D-TZ577 Card.
When replacing the card, contact its manufacturer for advice.
Plural PROFIBUS cards are set.
Only one card is accepted at any one time.
Install only one card.
PROFIBUS/CC-Link cards are set.
Either PROFIBUS or CC-Link card is accepted at any one time.
Install either a PROFIBUS card or a CC-Link card.
Either of the following messages is displayed:
(1) PROFIBUS self-check error n (n = 1~7).
(2) PROFIBUS cannot self-check
An error was detected in the hardware. The hardware may be at fault.
Replace the 2D-TZ577 Card.
When replacing the card, contact its manufacturer for advice.
Illegal param (PBMODE)
PBMODE parameters are not defined validly.
Correct PBMODE parameters. (0 - normal, 2 - self-diagnosis)
Exchange number cannot be set.
Power the system off and on again.
If the error recurs, contact the manufacturer for advice.
Illegal param (PBMC)
PBMC parameters are not defined validly.
Correct PBMODE parameters. (1 - Class 1, 2 - Class 2)