Hitachi AP1 Data Book page 147

4-bit single-chip microcomputer
Table of Contents

Advertisement

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - LCD-Ill
• ELECTRICAL CHARACTERISTICS - 2 (Ta
=
-20 to +75°C)
Item
Symbol
Test Conditions
Value
Unit
min.
max.
Halt Duration Voltage
V OH
HLT = O.1V
2.3
-
V
Halt Current
IOH
Yin =Vee,HLT=O.1V,
V OH = 2.3V
-
4.0
IlA
Halt Delay Time
tHo
100
-
Ils
Operation Recovery Time
tRe
100
-
IJ.S
HLT Fall Time
tfHLT
-
1000
IlS
HL T Rise Time
trHLT
-
1000
IJ.S
HLT"Low" Hold Time
tHLT
400
-
IlS
H L T "High" Hold Time
tO PR
R f Oscillation, External
100
-
IlS
Clock Operation
Power Supply Rise Time
tree
Built-in Reset, HLT = Vee
0.1
10
ms
Power Supply OFF Time
tOFF
Built-in Reset, H L T = Vee
1
-
ms
RESET Pulse Width (1)
tRST1
External Reset, H L T = Vee
1
-
ms
External Reset, Vee - 2.7
to 5.5V, HLT = Vee,
(Prescaler Clock = System
2' T inst
-
Clock)
Ils
RESET Pulse Width (2)
tRST2
External Reset, Vee = 2.7
to 5.5V, HLT = Vee,
32 x 10
6
/
-
(Prescaler Clock = Crystal
f
o,cx
Clock)
RESET Rise Time
trRST
External Reset,
RLT
= Vee,
-
100
IlS
Vee = 2.7 to 5.5V
RESET Fall Time
tfRST
External Reset, H L T = Vee,
-
100
IJ.S
Vee = 2.7 to 5.5V
INOTEI 1. Applied to PMOS load of CMOS output pins and CMOS I/O common pins among
0
and R terminals.
2. Applied to CMOS output pins, CMOS I/O common pins, input pins with pull up MOS, and I/O common pins with pull up MOS
among
0
and R terminals.
3. Applied to open<irain output pins and open<irain I/O common pins among 0 and R terminals.
4.
Pull up MOS currant is axcluded.
5.
Applied to the supply current when the LCD-III is in the reset state and the crystal oscillation for timer doesn't operate
ICurrent that flows in the input/ouljut circuit and in the power supply circuit for LCD is excluded).
Test Condition: RESET, HLT, EST
=
Vee IReset State I
INTo, INTI, Roo to R u , Do to
0
13
=
Vee
D I4 /XO, D u /XI,-D I4 /XO, D.1../XI
=
Vee (Crystal oscillation
~or ~imer
is
~ot
se!ectedl
LOu/XO - upen, Ou/XI .. VCC ICrystal OSCillation for timer
IS
selected).
~bM~2 toVC;M~~~EGI
to SEG
n
=
Open
Note
(14)
When tha crystal oscillation for timer operates, the standby supply current 121 IcCS2 flows in addition to Icc.
When the LCD-III is installed in the user's system, and in operation current increases according to the external circuitry and devices.
Those are connected to the LCD-III. User should design the power supply in consideration of this point IThe difference between
the measured current in the above reset stata and that measured in the operatio.nal state in tha user's system is the increased part of
the supply current!.
6. Standby I/O leakage current is the leakage current of I/O pins in the "Halt" and "Disable" state.
145