9.34 Panel PCB Unit
(1) Disconnect the Flat cable (CN4) of the Panel PCB unit and release the wiring.
CN4
■
A4 model
(2) Remove the three Taptite cup B M3x10 screws from the LCD hold plate.
(3) Release the four Hooks and remove the LCD hold plate from the Control panel ASSY.
LCD hold plate
Hook
Flat cable
Panel PCB unit
Fig. 3-139
Taptite cup B M3x10
Fig. 3-140
Control panel ASSY
Control panel ASSY
Hook
3-110
Confidential