Step 1 On the CLI of the converged switching plane, run the following command to go to the system
view:
<HUAWEI> system-view
The command output is as follows:
Enter system view, return user view with return command.
Step 2 Go to the user serial port view.
[~HUAWEI] user-interface console 0
Step 3 Open the user interface (UI) for changing the password.
[~HUAWEI-ui-console0] set authentication password
The command output is as follows:
Please configure the login password (8-16)
Enter Password:
Step 4 Enter a new password.
The password is case-sensitive and must meet the following requirements:
l
l
The following information is displayed:
Confirm Password:
Step 5 Enter the new password again. The following information is displayed:
Info: The password of ui-console0 will be changed, please verify the old password.
Please enter old password:
Step 6 Enter the old password. The following information is displayed:
Info: Change the password successfully.
Step 7 Submit the configuration.
Issue 09 (2019-08-02)
Default Data
l User name: root
l Password: Huawei12#$
Change the initial password for logging in to the GE switching plane over a serial port.
Contain at least two types of the following characters:
– Uppercase letters A to Z
– Lowercase letters a to z
– Digits 0 to 9
– At least one of the following special character: .`~!@#$%^&*()-_=+\|[{}];:'",<.>/
Cannot be the same as the user name or the user name in reverse order.
NOTE
The entered password is not displayed on the terminal screen.