Failure Code [Ca2185] Throt Sens Sup Volt High Error - Komatsu ecot3 PC300LC-8 Shop Manual

Hydraulic excavator
Table of Contents

Advertisement

SEN02630-05

Failure code [CA2185] Throt Sens Sup Volt High Error

Action code
Failure code
E14
CA2185
Contents of
• High voltage (5.25 V or higher) was detected in throttle sensor power supply circuit.
trouble
• If trouble occurs while starting switch is in ON position, controller fixes voltage value to level just
Action of con-
before detection of trouble and continues operation.
troller
• If starting switch is turned ON while voltage is abnormally high, controller continues operation with
voltage at 100% value.
Problem that
appears on
• Engine speed cannot be controlled with fuel control dial.
machine
Related infor-
• Method of reproducing failure code: Turn starting switch ON.
mation
Short circuit in wiring har-
1
ness
(with another wiring harness)
Possible causes
and standard
value in normal
Defective wiring harness
2
state
connector
3 Defective engine controller
Circuit diagram related to fuel control dial
42
Throttle sensor supply voltage high error
Trouble
(Engine controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
a
Between CE02 (female) (22) – each of CE02
(female) pins (With P20 disconnected)
Connecting parts between fuel control dial – machine wiring har-
ness – engine controller may be defective. Check them directly.
• Looseness of connector, breakage of lock, or breakage of seal
• Corrosion, bend, breakage, push-in, or expansion of pin
• Moisture or dirt in connector or defective insulation
If causes 1 and 2 are not detected, engine controller may be defec-
tive. (Since trouble is in system, troubleshooting cannot be carried
out.)
Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
40 Troubleshooting
1
Resis-
Min.
tance
100 kz
PC300, 350-8