Failure code [DWJ0KA] Merge-divider Sol. Open Circuit

Action code
Failure code
DWJ0KA
Contents of
• No current flows at output to merge-divider solenoid circuit.
trouble
Action of con-
• None in particular. (Since no current flows, solenoid does not operate.)
troller
• If cause of failure disappears, system resets itself.
Problem that
appears on
• Single operation speed of work equipment and swing is high in lifting mode (L).
machine
• Operating condition of merge-divider solenoid (ON/OFF) can be checked with monitoring function.
(Code 02300: Solenoid 1)
Related infor-
• Solenoid detects disconnection when output is turned on. To confirm the reproduction after repair, be
mation
sure to turn output on. (For more information on how to turn output on/off, see troubleshooting for
failure code [DWJ0KB].)
Defective merge-divider
1
solenoid
(Internal disconnection)
Disconnection in wiring har-
ness
2
(Disconnection in wiring or
Possible causes
defective contact in connec-
and standard
tor)
value in normal
state
Hot short (Short circuit with
3
24V circuit) in wiring harness
4 Defective pump controller
34
Merge-divider solenoid disconnection
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
a
a
Wiring harness between CP02 (female)
(112) – V03 (female) (2)
Wiring harness between V03 (female) (1) –
CP02 (female) (115), (117), (120) and chas-
sis ground
a
Wiring harness between CP02 (female)
(112) – V03 (female) (2) and chassis ground
a
Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
V03 (male)
Between (1) – (2)
Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
CP02 (female)
Between (112) –
(115), (117), (120)
40 Troubleshooting
1
Resistance
20 – 60 z
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Voltage
Max. 1 V
Resistance
20 – 60 z
PC300, 350-8