Failure Code [Dwj0Ka] Merge-Divider Sol Discon - Komatsu PC130-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC130-8:
Table of Contents

Advertisement

SEN04121-02

Failure code [DWJ0KA] Merge-divider sol discon

User code
Failure code
DWJ0KA
Contents of
• When merge-divider EPC solenoid was driven, disconnection was detected in circuit.
trouble
Action of
• None in particular (Since no current flows, solenoid does not operate).
controller
• If cause of failure disappears, system resets itself.
Problem that
appears on
• Single operation speed of work equipment and swing is high in lifting mode (L).
machine
Related
• Method of reproducing failure code: Turn starting switch ON.
information
Defective merge-divider EPC
1
solenoid (Internal disconnec-
tion)
Possible causes
Disconnection in wiring har-
and standard
ness (Disconnection in wiring
2
value in normal
or defective contact in con-
state
nector)
3 Defective pump controller
36
Merge-divider solenoid disconnection
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
a Prepare with starting switch OFF, then carry out troubleshoot-
a Prepare with starting switch OFF, then carry out troubleshoot-
Wiring harness between CP02 (female)
(112) – V02 (female) (2)
Wiring harness between CP02 (female)
(115), (117), (120) – V02 (female) (1)
a Prepare with starting switch OFF, then carry out troubleshoot-
Between (112) – (115), (117),
ing without turning starting switch ON.
V02 (male)
Between (1) – (2)
ing without turning starting switch ON.
ing without turning starting switch ON.
CP02 (female)
(120)
40 Troubleshooting
1
Resistance
20 – 60 z
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resistance
20 – 60 z
PC130-8

Advertisement

Table of Contents
loading

Table of Contents