SEN04120-03

Failure code [CA386] Sensor sup. 1 volt. high error

User code
Failure code
E15
Contents of
• High voltage was detected in sensor power supply 1 (5 V) circuit.
trouble
• Operates Bkup speed sensor with signals of Ne speed sensor.
• Sets atmospheric pressure sensor to default value (52.44 kPa {0.53 kg/cm
Action of
tion.
controller
• Fixes charge pressure sensor value (400 kPa {4.08 kg/cm
• Limits output and continues operation (Limits common rail pressure).
Problem that
appears on
• Output drops.
machine
Related
• Method of reproducing failure code: Turn starting switch ON.
information
1 Defective related system
Defective sensor (Internal
2
trouble)
Disconnection in wiring har-
ness
3
(Disconnection in wiring or
defective contact in connec-
tor)
Possible causes
and standard
value in normal
state
Ground fault in wiring har-
ness
4
(Short circuit with GND cir-
cuit)
Short circuit in wiring har-
ness
5
(With another wiring har-
ness)
6
Defective engine controller
8
Trouble
CA386
Causes
Sensor sup. 1 volt. high error
(Engine controller system)
Standard value in normal state/Remarks on troubleshooting
If another failure code is indicated, carry out troubleshooting for it.
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
Bkup speed sensor
Disconnect devices
at right in order. If
pressure sensor
error code disap-
pears when a device
Charge pressure
is disconnected, that
device has a defect
in it.
pressure sensor
a Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Wiring harness between ENG1 (female)
(36) – each sensor (female)
Wiring harness between ENG1 (female)
(48) – each sensor (female)
a Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Wiring harness between ENG1 (female)
(36) – each sensor (female) and chassis
ground
Wiring harness between ENG1 (female)
(48) – each sensor (female) and chassis
ground
a Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Wiring harness between ENG1 (female)
(36) – each sensor (female) and
Wiring harness between ENG1 (female)
(48) – each sensor (female)
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
ENG1
Between (36) – (48)
40 Troubleshooting
2
}) and continues opera-
2
}) and continues operation.
CAM connector
Atmospheric
PAMB connector
PTIM connector
sensor
Common rail
PFUEL connector
Resis-
tance
Resis-
tance
Resis-
tance
Resis-
tance
Resis-
tance
Voltage
4.75 – 5.25V
1
Max. 1 z
Max. 1 z
Min. 1 Mz
Min. 1 Mz
Min. 1 Mz