SEN04121-02

Failure code [DW91KB] Travel junction sol short

User code
Failure code
DW91KB
Contents of
• When output to travel junction solenoid was turned ON, short circuit was detected in circuit.
trouble
Action of
• Turns output to travel junction solenoid OFF.
controller
• Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF.
Problem that
appears on
• Machine is not steered easily during travel.
machine
• Operating condition of travel junction solenoid can be checked with monitoring function. 
Related
(Code: 02300 Solenoid 1)
information
• Method of reproducing failure code: Start engine + Steer machine with right and left travel levers.
Defective travel junction
1
solenoid (Internal short cir-
cuit or ground fault)
Possible causes
Ground fault in wiring har-
and standard
2
ness (Short circuit with GND
value in normal
circuit)
state
3 Defective pump controller
34
Travel junction solenoid system short
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
a Prepare with starting switch OFF, then carry out troubleshoot-
Between (2) – chassis ground
a Prepare with starting switch OFF, then carry out troubleshoot-
Wiring harness between CP02 (female)
(110) – V03 (female) (2) and chassis ground
a Prepare with starting switch OFF, then carry out troubleshoot-
Between (110) – (115), (117),
Between (110) – chassis ground
ing without turning starting switch ON.
V03 (male)
Between (1) – (2)
ing without turning starting switch ON.
ing without turning starting switch ON.
CP02 (female)
(120)
40 Troubleshooting
1
Resistance
20 – 60 z
Min. 1 Mz
Resis-
Min. 1 Mz
tance
Resistance
20 – 60 z
Min. 1 Mz
PC130-8