Failure Code [Dwk0Ka] 2-Stage Relief Sol Discon - Komatsu PC130-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC130-8:
Table of Contents

Advertisement

SEN04121-02

Failure code [DWK0KA] 2-stage relief sol discon

User code
Failure code
DWK0KA
Contents of
• When output to 2-stage relief solenoid is turned OFF, disconnection was detected in circuit.
trouble
Action of
• None in particular. (Since no current flows, solenoid does not operate.)
controller
• If cause of failure disappears, system resets itself.
Problem that
• Power maximizing function does not work.
appears on
• Travel power is low.
machine
• Operating condition of 2-stage relief solenoid can be checked with monitoring function. 
Related
(Code: 02300 Solenoid 1)
information
• Method of reproducing failure code: Turn starting switch ON + Set machine in mode other than (L).
Defective 2-stage relief sole-
1
noid (Internal disconnection)
Possible causes
Disconnection in wiring har-
and standard
ness (Disconnection in wiring
2
value in normal
or defective contact in con-
state
nector)
3 Defective pump controller
40
2-stage relief solenoid disconnection
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
a Prepare with starting switch OFF, then carry out troubleshoot-
a Prepare with starting switch OFF, then carry out troubleshoot-
Wiring harness between CP02 (female)
(109) – V06 (female) (2)
Wiring harness between CP02 (female)
(115), (117), (120) – V06 (female) (1)
a Prepare with starting switch OFF, then carry out troubleshoot-
Between (109) – (115), (117),
ing without turning starting switch ON.
V06 (male)
Between (1) – (2)
ing without turning starting switch ON.
ing without turning starting switch ON.
CP02 (female)
(120)
40 Troubleshooting
1
Resistance
20 – 60 z
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resistance
20 – 60 z
PC130-8