Travel Speed Is Low - Komatsu PC130-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC130-8:
Table of Contents

Advertisement

40 Troubleshooting
H-17 Travel speed is low
Trouble

• Travel speed is low.

Related
• Conduct the troubleshooting in working mode P.
information
Malfunction of self-pressure
1
reducing valve
Malfunction of travel PPC
2
valve
Malfunction of pump merge-
3
divider valve
Possible causes
and standard
value in normal
state
4 Malfunction of unload valve
Malfunction of pump merge-
5
divider valve
Malfunction of travel control
6
lever (spool)
Malfunction of travel control
7
lever (pressure compensa-
tion valve)
Malfunction of travel control
8
lever (suction valve)
9 Travel motor defective
10 Final drive defective
PC130-8
Cause
a
a
Forward or reverse position
a
a
The pump merge-divider valve may have a malfunction. Check it
directly.
The spool of the travel control lever may have a malfunction.
Check it directly.
The pressure compensation valve of the travel control lever may
have a malfunction. Check it directly.
The suction valve of the travel control lever may have a malfunc-
tion. Check it directly.
a
The final drive may have a defect in it. Check it directly. (It may be
checked by abnormal sound, abnormal heating, metal chips in
drain oil, etc.)
Standard value in normal state/Remarks on troubleshooting
Keep the engine stopped for the preparations, and keep it
running at high idle during the troubleshooting.
Control levers
All levers in NEUTRAL
Keep the engine stopped for the preparations, and keep it
running at high idle during the troubleshooting.
Travel lever
Difference in above output
between both sides
Keep the engine stopped for the preparations, and keep it
running at high idle during the troubleshooting.
Travel lever
All levers in NEUTRAL
Position for travel only
(On either or both sides)
Keep the engine stopped for the preparations, and keep it
running at high idle during the troubleshooting.
Control levers
All levers in NEUTRAL
Keep the engine stopped for the preparations, and keep it
running at high idle during the troubleshooting.
Travel lever
Travel circuit relieved
SEN04124-00
Control circuit basic pressure
3.2 ± 0.5 MPa
{33 ± 5 kg/cm
}
2
PPC valve output pressure
Above 2.7 MPa
{Above 28 kg/cm
}
2
Below 0.4 MPa
{Below 4 kg/cm
}
2
Solenoid valve output pressure
0 MPa {0 kg/cm
}
2
2.84 – 3.43 MPa
{29 – 35 kg/cm
}
2
Unload pressure
2.8 ± 1.0 MPa
{28 ± 10 kg/cm
}
2
Leakage from travel motor
Below 1.7 l/min
1
19

Advertisement