Failure Code [Dhx1Ma] Overload Sensor Abnormality (Analog) - Komatsu PC130-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC130-8:
Table of Contents

Advertisement

SEN04121-02

Failure code [DHX1MA] Overload sensor abnormality (Analog)

User code
Failure code
DHX1MA
Contents of
• Monitor which is not set to be displayed (Overload alarm monitor) is displayed.
trouble
Action of
• None in particular.
controller
• If cause of failure disappears, system resets itself.
Problem that
appears on
machine
Related
Method of reproducing failure code: Turn starting switch ON.
information
Possible causes
and standard
value in normal
1 Defective pump controller
state
24
Overload sensor (Analog)
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
Pump controller may be defective. (Since trouble is in system, trou-
bleshooting cannot be carried out.)
40 Troubleshooting