Technical Data - Siemens SINAMICS S120 Equipment Manual

Water-cooled chassis power units for common cooling circuits
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor-side power components
7.2 Motor reactors
7.2.4

Technical data

Table 7- 7
Technical data of motor reactors 380 V ... 480 V 3 AC, Part 1
Article number
Suitable for Power Module
Suitable for Motor Module
Type rating of Power Module or Mo-
tor Module
Rated current
Power loss
- at 50 Hz
- at 150 Hz
Connections
- To the Power Module or Motor
Module (1U1, 1V1, 1W1)
- Load (1U2, 1V2, 1W2)
- PE
Max. permissible cable length be-
tween the motor reactor and motor
- without motor reactor
- for 1 motor reactor
- for 2 motor reactors in series
Degree of protection
Dimensions
Width
Height
Depth
Weight, approx.
190
6SL3000-
2BE32-1AA0
6SL3315-
1TE32-1AA3
6SL3325-
1TE32-1AA3
kW
110
A
210
kW
0.436
kW
0.486
M10
M10
M8
m
m
m
IP00
mm
300
mm
285
mm
257
kg
66
2BE32-6AA0
2BE33-2AA0
1TE32-6AA3
1TE33-1AA3
1TE32-6AA3
1TE33-1AA3
132
260
0.454
0.5
M10
M10
M8
300 (shielded) / 450 (unshielded)
300 (shielded) / 450 (unshielded)
525 (shielded) / 787 (unshielded)
IP00
300
315
277
66
Water-cooled chassis power units for common cooling circuits
Manual, 08/2017, 6SL3097-4AM10-0BP0
2BE35-0AA0
1TE35-0AA3
1TE35-0AA3
160
250
310
490
0.422
0.448
0.47
0.5
M10
M12
M10
M12
M8
M8
IP00
IP00
300
300
285
365
257
277
66
100

Advertisement