Operating A Service Pc/Pc In The Network; Overview - Siemens SINUMERIK 840D sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

3. In Symantec Ghost, select the "From Image" command from the "Local > Disk" menu.
4. Select
Result
The Emergency Boot System is installed on the USB flash drive and the data medium is
renamed to "EBOOT." The service system on the bootable USB flash drive can now be
used.
5.10

Operating a service PC/PC in the network

5.10.1

Overview

System network
In the following applications, you will need, for example, a connection between the PCU and
a PG/PC in the system network:
● Save the disk image of the PCU-SSD to a PG/PC
● Restore the SSC of a PCU via the DVD drive of a PG/PC
● Start up the replacement SSD
● Install the software on the PCU via the DVD drive of a PG/PC
Company network
If you want to connect the service PG/PC via a company network (Eth 1), contact your
network service center.
PCU Base Software (IM10)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
as the source and the USB flash drive as the destination.
D:\Eboot\eboot.gho
Backing up and restoring data
5.10 Operating a service PC/PC in the network
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents