Adapting the version file
The cycles version specification requires a manual adaptation of the version file.
1. Copy the "versions.xml" sample file from the following directory:
2. Store the sample file in its own directory under /oem, e.g. /oem/sinumerik/cycles
3. Open the file.
4. Enter the planned version for the cycles files in the <info> tag with "defaultFileVersion"
5. Close the file to save the changes.
Example:
<info defaultFileType=" *.spf *.cpf" defaultFileVersion="05.05.00.00"
linkname="CMA" linkpath="//NC/CMA.DIR" EffDirOrder="CUS CMA">
<Name>Manufacturer cycles</Name>
<Version>5.5.0.0</Version>
<Link>
<Name>CUS</Name>
<Path>//NC/CUS.DIR</Path>
</Link>
</info>
Adapting the version path file
The cycles version specification requires that the path details are entered manually in the
version path file.
1. Open the versions.xml file under /oem
2. Replace the standard path in the <Path> tag for the "Manufacturers Cycles" with your
3. Close the file to save the changes.
Standard:
<Component>
<Name>Manufacturer Cycles</Name>
<Path>/siemens/sinumerik/hmi/data/version/oem/cma</Path>
</Component>
Example:
<Component>
<Name>Manufacturer Cycles</Name>
<Path>/oem/sinumerik/cycles</Path>
</Component>
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
/siemens/sinumerik/hmi/data/version/oem/cma
and the details for the complete version in the <Version> tag.
own path for the version file.
Configuring cycles
22.11 Compare cycles version