Configuring alarms
13.2 Configuring alarm and message texts via alarm text files
Example
<?xml version="1.0" encoding="UTF-8" standalone="yes"?>
<!-- Configuration of the Solutionline Alarm & Event Service Adapter -->
<CONFIGURATION>
</CONFIGURATION>
Restart SINUMERIK Operate
The files must still be converted into a binary format so that the alarm texts can be displayed
during the program runtime. This data is only converted during power up.
To do this, restart SINUMERIK Operate. In the same directory where the .ts files are located,
files with the same name are created with the ".qm" file extension.
The result of the conversion is written to the "alarmtext_conversion.log" or
"oem_text_conversion.log" file. Errors that occur during the conversion, such as syntax
errors in a parameter file, are also written to the file.
This file is saved in the /user/sinumerik/hmi/log directory.
Note
The conversion is only made if the .ts file is newer than the associated .qm file.
13.2.4
Changing alarm attributes
Color types of the alarms
You can individually change the colors of the alarms and messages displayed in the
message line.
You can change the following for each alarm number and alarm source:
● Font color of the alarm/message text
● Background color of the alarm/message text
● Font color of the alarm number
● Background color of the alarm number
208
<Connections>
<PartprogramMessageChannel_02>
<ContextName type="QString" value="partprogmsg02"/>
</PartprogramMessageChannel_02>
</Connections>
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
SINUMERIK Operate (IM9)