Data backup
15.1 Creating a start-up archive
15.1
Creating a start-up archive
Overview
A start-up archive can be generated, for example, after the controller has been
commissioned. To do this, control components can be saved individually or jointly. It is also
possible to transfer the backed-up data to other controllers so that they can be updated to
the same status.
Precondition
You require at least access level 2 (service).
Data of the control components
Control components
NC data
PLC data
Drive data
HMI data, all
278
With compensation
data
with compile cycles
Data
Machine data
Setting data
Option data
Global (GUD) and local (LUD) user data
Tool and magazine data
Protection zone data
R parameters
Zero offsets
Workpieces, global part programs and subprograms
Standard and user cycles
Definitions and macros
QEC - quadrant error compensation
•
CEC - operation/angularity compensation
•
EEC - leadscrew pitch / encoder error compensation
•
It only makes sense to archive machine-specific compensation
data if the start-up file is reloaded into the same controller.
Compile cycles (*.elf) are displayed, if compile cycles are
available.
OB (organization blocks)
FB (function blocks)
SFB (system function blocks)
FC (functions)
SFC (system functions)
DB (data blocks)
SDB (system data blocks)
Archiving the drive data, either in the binary or ASCII format.
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
SINUMERIK Operate (IM9)