2.2.6
Copying easyscreen.ini into the OEM directory
Storage path
Copy the file easyscreen.ini from the directory
card/siemens/sinumerik/hmi/cfg
to the directory
card/oem/sinumerik/hmi/cfg
2.2.7
Registering the COM file in easyscreen.ini
Adaptation in easyscreen.ini
Make the following change in the
registered the ma_auto.com configuration file.
[STARTFILES]
;<===============================================================>
;< OEM Softkey on horizontal Machine-Automatic Menu
;< SOFTKEY position="6"
;<===============================================================>
StartFile03 = area := AreaMachine, dialog := SlMachine, menu :=
SlMaAutoMenuHU, startfile := ma_auto.com
2.2.8
Testing the project
Testing the dialog call
In the machine operating area, change to the AUTO mode. Click on the "START" softkey.
If "Run MyScreens" detects errors when interpreting the configuration files, these errors will
be written to the easyscreen_log.txt ASCII file (see Chapter Troubleshooting (log book)
(Page 26))..
Testing context sensitive help screens and online help
Test the context sensitive help screens and the online help. If errors occur, then check the
paths where files have been saved.