Configuring alarms
13.3 Configuring an alarm log
Examples
Log all alarms with a ClearInfo not equal to 15, i.e. no part program messages:
<CONFIGURATION>
</CONFIGURATION>
Log all alarms with the SourceURL "/NCK" or "/HMI":
<CONFIGURATION>
</CONFIGURATION>
In the <FilePath> tag, adapt the path and file name for the file in which the alarm log is
stored persistently:
<CONFIGURATION>
</CONFIGURATION>
224
<Protocol>
<Filters>
<Siemens_Filter_01 type="QString" value="CLEARINFO NOT 15" />
</Filters>
</Protocol>
<Protocol>
<Filters>
<Filter_01 type="QString" value="SourceURL EQUAL /NCK" />
<Filter_02 type="QString" value="SourceURL EQUAL /HMI" />
</Filters>
</Protocol>
<Protocol>
<Filters>
<FilePath type="QString" value="$(HMI_INSTALL_DIR)user/sinumerik/hmi/
log/alarm log/slaepp " />
</Filters>
</Protocol>