2.5.1 Connecting Low DC Power

2.5.1
Connecting Low DC Power
To connect a low DC power supply to the device, do the following:
Electrical hazard – risk of damage to equipment
Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block.
Damage to the power supply may occur.
Electrical hazard – risk of damage to equipment
In normal operation, the jumper between the chassis ground and surge ground ter-
minals must be installed for proper operation. Damage to the device may occur oth-
erwise. Removing the jumper may also void the warranty.
Note
The RUGGEDCOM RX1512 works with both positive VDC power supplies and negative
VDC power supplies.
Note
For information about how to safely test the dielectric strength of the device, refer to