Environmental Type Tests - Siemens RUGGEDCOM RX1512 Installation Manual

Simatic net industrial ethernet switches
Hide thumbs Also See for RUGGEDCOM RX1512:
Table of Contents

Advertisement

IEC 61000-4-17
IEC 61000-4-29
IEC 60255-5
a
Siemens-specified severity levels
EMC Immunity Type Tests for IEEE 1613
Note
The RUGGEDCOM RX1512 meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports. Class 1 allows for temporary communica-
tion loss, while Class 2 requires error-free and interrupted communications.

Environmental Type Tests

RUGGEDCOM RX1512
Installation Manual, 07/2019, C79000-G8976-1057
Test
Ripple on DC
Power Supply
Voltage Dips
and Interrupts
Dielectric Strength
HV Impulse
Description
HV Impulse
Dielectric Strength
Fast Transient
Oscillatory
Radiated RFI
ESD
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
6.2 EMC and Environmental Type Tests
Description
DC Power Ports
DC Power Ports
Signal ports
DC Power Ports
Signal ports
DC Power Ports
Signal ports
DC Power Ports
Signal ports
DC Power Ports
Signal ports
DC Power Ports
Earth ground ports
Signal ports
DC Power Ports
Enclosure ports
Enclosure Contact
Enclosure Air
Description
Cold Temperature
Test Ad
Dry Heat
Test Bd
Humidity (Damp
Test Db
Heat, Cyclic)
Vibration
Certification
Test Levels
10%
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Failsafe Relay output)
2 kV
5 kV (Failsafe Relay output)
5 kV
Test Levels
5 kV (Failsafe Relay Output)
5 kV
2 kV
2 kV
± 4 kV @ 2.5 kHz
± 4 kV
2.5 kV common mode @1MHz
2.5 kV common
1 kV differential mode @ 1 MHz
35 V/m
± 8 kV
± 15 kV
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2 g @ 10-150 Hz
Severity
Levels
3
 
 
Severi-
ty Levels
 
 
 
Class 2
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic net ruggedcom rx1512

Table of Contents