5 Configuring
5.24 FX 8 Presetting of tool size via EPROM
Formula for calculating the data block length:
y = x + (ANPL + 1)
ANPL =
Number of magazine locations
x
=
Number of 1st data word
y
=
Number of last data word
Initial setting:
In the initial setting, the function block deletes the status words of the FBs (DB 150, DW 256 -
DW266) and checks whether the DB EPROM is available. It also checks whether the contents
of the left decade of all the data words is "0" (bits 12 - 15), the only permissible value is FFh
"Synchronization pattern".
If any errors are detected, the PLC is stopped!
Operation:
The function block checks whether the DLx in the DB EPROM contains the synchronization
pattern "FF". It is checked whether the magazine which is to be configured is available and
whether it is a fictitious magazine.
The function block checks whether a tool size has already been entered at every magazine
tool location (check data words for "0"; 50 DW/cycle).
If no error is detected, the tool size is preset in the next PLC cycle.
If an error is detected, the error output of the FB is set and an error number is stored in DBZW
DW 256.
Presetting:
To preset the tool size, the current # magazine locations are entered in DBZW in DW 47 -
DW 78. The current magazine length must not exceed the set length; (# locations from
EPROM # locations from magazine).
Block data
Lib. No.
: E88530-B 6608-A-50
FBs to be loaded
: FX 8, FB 131, FB 132
FBs to be loaded
: None
Type of FB call
: Unconditional or conditional
DBs to be input
: DBEP
Error messages
: %1
%2
5–102
(DR x)
(DW x)
(DW y)
DB-EPROM not available!
ACCU 1: (1008), ACCU 2: (0001)
Bit 12-15 in DB EPROM >< 0!
ACCU 1: (1008), ACCU 2: (0002)
DW 256 (data word no.)
3
Specifies magazine number 1 or 16
for SINUMERIK 880/880 GA2
Specifies magazine number 1 or 4
for SINUMERIK 840/840C
4
# locations from EPROM > # locations from magazine
5
Location assigned with tool size DW 256 (location no.! error no.)
6
Invalid DW address in EPROM (DLx >< FF; DRx = 0)
7
No fictitious magazine
© Siemens AG 1991 All Rights Reserved