5 Configuring
5.5 FB 120 Unloading via tape
Block call FB120
FB LOCHSTAG
DB 135,
STW
DW 11
DW 12
Signal descriptions
E-SP
Read-in disable
K-DB
Channel-specific data block
FEHL
DB 135 DD 100
– If an error occurs, the error number which is transferred to the NC
STW
Control words for internal states; DB 135, DW 11, DW 12
Example of a call with read-in disable:
FB xxx
Name
: LOCHSTAG
:
:
: JU FB120
NAME
: LOCHSTAG
E-SP
: F 222.0
K-DB
: FY 221
:
: L FY221
: L KB135
: ! = F
: JC = WEIT
:
: B FW 220
: Q DB 0
: A F 222.0
: = D 9.0
WEIT
:
:
Functions
Function code: = bit No. of DL 17 in DB135
Backup:
Function code: 0
Unloading of magazines 1 to 16,
including tool buffer
Parameters:
5–16
E-SP
K-DB
F-NR
cycle appears.
Tape output
Flag read-in disable
Channel-specific DB
Only this part has to be programmed if FB155 is also called
in the user program; otherwise the call can be continued
with "B FW 220"
Channel-specific DB
Read out read-in disable
and write into data 9
None
© Siemens AG 1991 All Rights Reserved
Q, BI
Q, BY (KF)
DBZW, DR 246 (KF)
6FC5 197-0AA40-1BP1
SINUMERIK 840/880 (PJ)
02.93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840cSinumerik 880Sinumerik 880 ga2

Table of Contents