11.92
Block call FB 132
I, BY (KF)
Signal descriptions
MANR
Submagazine number
When MANR = 1...16
which the machine data bits are transferred from DB61 to output parameters
MD 1...MD 4.
When MANR = 0, the global machine data words are output at output parameters
MD 1...MD 4.
MD-1
Machine data 1
When MANR = 1...16
When MANR = 0:
MD-2
Machine data 2
When MANR = 1...16
When MANR = 0:
MD-3
Machine data 3
When MANR = 1...16
When MANR = 0:
MD-4
Machine data 4
When MANR = 1...16
When MANR = 0:
F
Error bit
The error output carries a "1 signal" when the defined magazine number > 16
when the submagazine is not defined ((MD 7010.0) + n = 0; n = 1...16
_______
1)
SINUMERIK 840/840C 1...4
© Siemens AG 1991 All Rights Reserved
SINUMERIK 840/880 (PJ)
5.10 FB 132 Subroutine: Submagazine-specific machine data words
FB UP:TMD-W
MANR
MD-1
MD-2
MD-3
MD-4
F
1)
, the input parameter states the submagazine number for
1)
:
MD-1 =Initial address of submagazine
MD-1 =Initial address of tool buffer
1)
:
MD-2 = Number of magazine locations (current length)
MD-2 = Number of tool buffer positions
1)
:
MD-3 = Tool offset area assigned to magazine
MD-3 = Width of magazine table (#DBs)
1)
:
MD-4 = Number of assigned background magazine
MD-4 = Width of reference list (#DBs)
6FC5 197-0AA40-1BP1
Q, W (KF)
Q, BY (KF)
Q, BY (KF)
Q, BY (KF)
Q, BI
1)
)
5 Configuring
1)
or
5–35