Panasonic YD-350GL4 Operating Instructions Manual page 17

Digital igbt controlled mig / mag arc welding power source
Table of Contents

Advertisement

NO.
name
4
Jog-dial
voltage display
5
7-segment LED
setting
" voltage "
" arc length "
" arc
6
characteristics "
" penetration
control "
function select
Names and functions
● When Mode selection key ○
)・ when key ○
selects different options, please adjust corrosponding
3
3
set value according different items.
・During welding, " Welding " current can be adjusted. However " initial "
and " crater " current can NOT be changed.
● When Mode selection key
refer to detailed description.
● When Mode selection key ○
・ It does not function.. ( When" Call " is selected, only Jog-dial ○ 7 , key
, ○
, ○
work. )
8
10
12
● When Mode selection key ○
・ It does not function.. (When " Call " is selected, only Jog-dial ○
, ○
, ○
work. )
8
10
12
● When Mode selection key ○
・On stand-by status, ○ 6 data of the item being selected is shown.
・During welding, it shows the voltage value of the actual output.
● When Mode selection key ○
・It shows specific set values.
● When Mode selection key ○
・Use Jog-dial ○
to select channel number. LED shows corresponding
7
channel number. If the welding parameters are avilable in the channel, the
channel can be selected, else the corresponding channel can NOT be
selected. When the channel stored with data is selected, the channel and
parameters are displayed alternately and welding can start.
● When Mode selection key ○
・By turning the Jog-dial ○
"CH" setting current and voltage. The flashing means welding parameters
to be stored.
・Press selection key ○
12
corresponding parameters are recorded in the channel being selected.
● When a self-diagnosable error occurs, ( For troubleshooting:
Section 13.1)
・ It shows alarm signal number.
● When "voltage"/ "arc length " function is selected, the setting method of
the corrosponding selection number is decided by P11 of "F. Adj" function
menu. When P11 is 0, it is adjusted by wire feeder potentiometer; when
P11 is 1, it can be changed by Jog-dial ○
● When" arc characteristics " function is selected, the value can be
changed by Jog-dial ○
7
● When"penetration control " function is selected, the value can be
changed by Jog-dial ○
7
Note: To change"penetration control ", welding method ○ 14 is to be
selected as "Deepen ".
13
description
is set to " Weld ", (refer to description in
12
12 is set to "F. Adj",(
is set to " Call ",
12
is set to " Record ",
12
is set to " Weld ",
12
is set to "F. Adj", (
12
is set to " Call ",(
12
is set to " Record ", (
12
, channel number can be selected. LED shows
7
to return to " Weld " from " Record " and the
7
Section 5.4) ・
, key
7
Section 5.4)
Section 5.6)
Section 5.6)

Hide quick links: