11. Troubleshooting
WARNING
To ensure safety, troubleshooting work shall be done by qualified personnel.
Make sure to turn off the power and other switches of all
taking any actions for correcting an error.
*: Includes this product, the distribution box and other related devices (jigs, robots, etc.).
In case of performing the inside inspection, make sure to work at least five minutes after the
power is turned off (for capacitor discharge).
11.1  Error indication
●When a self-diagnosable error occurs, "Err" (for error) and error code can be displayed on the
operation panel.
See the following table for details of the error codes.
(Note) About "Group" in the table
• Group "A": It is not necessary to turn power switch OFF. (The displays are automatically turned
off when the cause is removed.)
• Group "B": It is necessary to turn power switch OFF and back ON again. (The displays can NOT
be automatically turned off until the power switch is turned OFF even when the cause is
removed.)
● after connecting the power source, 7-segment display cannot be shown normally.
Err
S/N
Err
001
Err
002
Err
003
Touching the current-carrying parts may cause a fatal electric shock or
burn injury.
To prevent a physical accident, such as an electric shock, burn injury, etc., make
sure to observe the followings.
Error type
Group
The connection of external equipment emergency stop on
the output terminal block.
● Turn power switch OFF, refer to the list below and
emergency
remove the cause and then turn power switch ON again.
B
stop
· malfunction from external equipment emergency stop.
· malfunction from switch power source PCB in this
equipment.
Over-current due to short-circuit in the secondary circuit
secondary
or so on.
over-current
A
● Turn welding gun switch OFF and remove the cause of
error
the over current.
Rise in temperature inside this welding power source.
Please do NOT turn OFF the machine before the
temperature in the Product decreases.
<Remedy>
Keep the input power in no load state and wait for a
while. The error code indication automatically turned off
temperature
when the power source is cooled down.
A
rise error
Check and remove causes of over-heat.
• Over duty cycle,
• Air flow blocking at ventilation and cooling fan
windows
If the problem cannot be solved by the above-mentioned
activities, please clean the cooling fan.

Troubleshooting

devices*
Probable causes and remedy
37
for safety reasons before

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yd-500gl4

Table of Contents