Panasonic YD-350GL4 Operating Instructions Manual page 42

Digital igbt controlled mig / mag arc welding power source
Table of Contents

Advertisement

Err
S/N
Error type
primary
Err
004
over-voltage
primary
Err
005
under-voltage
Arc Start
Err
006
error
welding gun
Err
007
switch error
current
Err
008
detection
error
external
Err
010
interruption 1
external
Err
011
interruption 2
wire
Err
019
adhesion
error
motor
Err
025
encoder error
wire feeder
Err
028
over-current
error
●If alarm message listed below frequently prompts, please contact with Distributor.
Err
S/N
Error type
RAM
Err
030
error
communication
Err
050
error
Troubleshooting
Group
Probable causes and remedy
The input voltage exceeds allowable range (higher than
AC 437V).
B
● After input voltage returns within the allowable range,
then turn power switch back ON again.
The input voltage is lower than allowable range (lower
than AC 304V) or input power source phase failure
happens.
● After input voltage returns within the allowable range,
then turn power switch back ON again.
B
Note: when welding machine input power source phase
failure happens, apart from ERR-5, the operation PCB
shows nothing (i.e. LED indicator and LED display are
not lit), or operation PCB LED indicator and LED display
alternately flashes.
Neither arc is generated nor no-load voltage is detected
when the torch switch is turned on.
When the "Arc Start" error occurs, the welding current
B
output, motor of the wire feeder and shielding gas flow
are stopped automatically.
● Switch off power source switch, remove the cause of the
arc ignition error.
The torch switch was turned on before turning on the
power switch.
A
● Turn welding gun switch or inching wire feeding button
OFF.
Output current or voltage is detected when the power
switch is turned on.
<Remedy>
Turn power switch OFF and then check the followings to
B
remove the cause(s).
• This product is defective.
• Check if the current or voltage is applied to the
secondary side of this product from an external device.
The external equipment the connecting to output terminal
block receives interruption signal " temporary stop 1".
●Remove the cause on the external equipment side.
The external equipment the connecting to output terminal
block receives interruption signal " temporary stop 2".
●Remove the cause on the external equipment side.
When the Product works with special purpose machine or
robot, wire adhesion at the end of welding.
B
● switch off power source switch and cut the welding
wire.
Abnormal encoder feedback
B
● Switch off power source switch to eliminate arc
abnormal ignition factor.
The wire feeding route is blocked, causing over-load of
the motor.
B
●clean the wire feeding route ( contact tip, wire feeding
liner and wire feeding roller etc.).
Group
Probable causes and remedy
Abnormal RAM.
● restart power source, confirm the data of F. Adj
menu. If data disappears, please set again.
Abnormal communication.
● restart power source.
38