Fujitsu FLM 150 ADM Maintenance And Trouble Clearing page 194

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
Step 3
Retrieve the Group Configuration to show how the slot is provisioned.
RTRV-SYS:TID::CTAG;
Is the group provisioned correctly?
Call the Fujitsu Technical Assistance Center at
1-800-USE-FTAC (1-800-873-3822) for assistance.
WARNING:
The following action has the potential for dropping traffic if not done correctly!
Delete any cross-connects that exist to/from the group. Repeat as necessary.
Step 4
DLT-CRS-AIDTYPE:TID:from,to:CTAG::CCT;
where the AIDTYPE = VT1 or STS1 and CCT = 1WAY or 2WAY.
WARNING:
Do not use CCT=1WAYBD with a DLT-CRS command, Your may inadvertently drop
the "continue" portion of a "Drop and Continue" circuit. Use 1WAY instead.
Step 5
If any of the facilities in the applicable group are in service, place them out of
service.
DLT-AIDTYPE:TID:AID:CTAG;
where the AIDTYPE = T1, T3, OC12, OC3, OVTG, EC1, ATMVC, LMP, LBP, or
T3U.
Step 6
Place the equipment slots for the group out of service starting with the lower
speed unit and progressing to the higher speed units.
DLT-EQPT:TID:AID:CTAG;
Step 7
Change the Group Configuration by using the following command.
ED-SYS:TID::CTAG:::CONFx-y
where x = appropriate group number and y = unit type.
Issue 9, May 1999
If Yes:
FNC and FNC Customer Use Only
5.8: Correcting a Mismounted Unit
If No:
Go to Step 4.
Vol. ll, Page 480.5-32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents