Maintenance and Trouble Clearing
FJTU-320-515-480
3.17
CLEI-TEMP
Table 3-15: CLEI-TEMP (Laser Temperature Increased)—Standing Condition
AID
Direction
Type
EQPT
NA
3.18
CPY Conditions
The following are the definitions of the CPY conditions:
•
CPY-FILE-PRTL (Copy file status is partial.)
•
CPY-FILE-FAIL (Copy file status is failed.)
•
CPY-FILE-COMPL (Copy file status is complete.)
•
CPY-MEM-FAIL (Copy memory status is failed.)
•
CPY-MEM-COMPL (Copy memory status is complete.)
Table 3-16: CPY Conditions (CPY-FILE-PRTL, CPY-FILE-FAIL, CPY-MEM-FAIL)—Transient
AID
Direction
Type
FILE
NA
Issue 9, May 1999
Probable Cause
• The temperature of the
laser transmitter has
exceeded a preset threshold.
• The ambient air
temperature is too high.
• The thermoelectric cooling
unit in the laser transmitter
has failed.
Conditions
Probable Cause
Attempted to copy file or
memory when another copy file/
memory is still active.
FNC and FNC Customer Use Only
Suggested Corrective Action
• Check site ambient temperature and/or
cooling system.
• Check shelf airflow for obstructions.
• Replace optical transmitter unit.
Suggested Corrective Action
Check the SWDL lead on the SV1A-TDL1 unit.
Wait until the LED is off (or until COMPL MSG is
received) before attempting CPY-FILE or
CPY-MEM.
3.17: CLEI-TEMP
Vol. ll, Page 480.3-14