Wkswpr - Fujitsu FLM 150 ADM Maintenance And Trouble Clearing

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
3.79

WKSWPR

Condition code that reports the switching from the Working unit to the Protect
unit in the FLM 150 ADM.
Table 3-77: WKSWPR (Working Facility/Equipment Switched to Protection)—
AID
Direction
Type
EQPT
NA
OC3
OVTG
STS1
VT1
Issue 9, May 1999
Transient Condition
Probable Cause
• LOS or degraded
signal input of the
Working unit
• Faulty Working unit
• Working unit removed
from chassis
FNC and FNC Customer Use Only
Suggested Corrective Action
• Has Working unit been removed? If not, signal
analysis should be performed to verify condition of
circuit.
• If signal is present and not degraded, replace faulty
Working unit.
• Replace unit.