Fujitsu FLM 150 ADM Maintenance And Trouble Clearing page 195

Table of Contents

Advertisement

Maintenance and Trouble Clearing
FJTU-320-515-480
Step 8
Has the mismount cleared?
If Yes:
Go to Step 9.
Step 9
Place the equipment slots back in service starting with the higher speed unit and
progressing to the lower speed units.
ENT-EQPT:TID:AID:CTAG;
Step 10
Place the facilities back in service.
ENT-AIDTYPE:TID:AID:CTAG;
where the AIDTYPE = T1, T3, OC12, OC3, OVTG, EC1, ATMVC, LMP, LBP, or
EQPT.
Were any cross-connects deleted in Step 4 that must be reconnected?
Step 11
Go to Step 12.
Step 12
Restore the cross-connects deleted in Step 4. Repeat as necessary.
ENT-CRS-AIDTYPE:TID:from,to:CTAG::CCT;
where the AIDTYPE = VT1 or STS1 and CCT = 1WAY or 2WAY.
You have completed this procedure.
Issue 9, May 1999
Call the Fujitsu Technical Assistance Center at
1-800-USE-FTAC (1-800-873-3822) for assistance.
If Yes:
You have completed this procedure.
FNC and FNC Customer Use Only
5.8: Correcting a Mismounted Unit
If No:
If No:
Vol. ll, Page 480.5-33