7. Before starting the motor by choosing Motor on (see Fig. 4-8), you have to
make the following settings:
– Enter a speed setpoint (e.g. 50 revolutions per minute).
– Use the slider to set the setpoint in %. Position your cursor on the slider,
hold down the left mouse button, and set the speed to 0%.
Danger
!
During commissioning, note the machine traversing range and take appropriate
external measures (e.g. monitoring the limit switch).
Fig. 4-8
8. Choose Drive on. The ON/OFF1 "enable" command is set and displayed on
the control panel (see Fig. 4-9).
ON/OFF1 "enable"
command set.
Fig. 4-9
9. Move the slider for the speed slowly from 0 to 100% (see Fig. 4-9).
The motor starts to rotate.
10.When you choose Stop, the motor stops. You can also trigger a fast stop by
pressing the space bar.
 Siemens AG, 2004. All rights reserved
SINAMICS S120 Getting Started with the STARTER Commissioning Tool – 04.2004 Edition
Using the STARTER Control Panel (Motor Rotates)
8.
Drive on.
Control panel before "Drive on"
10. Stop
The motor starts to rotate
Speed setpoint: 50
Percentage to 0%
9. Increase the speed slowly
from 0 to 100%.
4-55