Diagnostics/Service
8.3 Action log
Switching functions on and off via the HMI interface
You reach the "Action Log Settings" menu via the "HMI" → "Action Log" softkeys in the
"Commissioning" operating area. The following information and selection options are
available:
● Logging on
● Path of the log file: /card/user/sinumerik/hmi/action.com (not modifiable)
● Size of log file: 5000000 (default setting, in bytes)
● Write delay for file:
● Program status when an alarm occurs: Input of alarms. These alarms directly trigger
Log events
If the action log is switched on, the following log events are activated:
Interrupts
Keys
Channel status
Window switchover
Writing NCK/PLC
data
PI Services
(program invocation)
The following current program statuses are logged under "Curr. program status":
114
– 1: (Default setting) Log entries are only written to the CompactFlash card if the internal
buffer is full. If the control system is switched off, entries in the internal buffer may be
lost.
If a PLC crash signal is output or the action log is activated/deactivated, the entries
are always saved.
– 0: These log entries are stored consecutively on the CompactFlash card. This can
impair its performance and reduce its service life.
– >0: Time (in seconds), after which the internal buffer is written to the CompactFlash
card.
writing of the current action log to the CompactFlash card. If several alarm numbers are
entered, they must be separated by commas.
Logging all incoming and outgoing alarms/messages of the NC/PLC and HMI-
Embedded
Logging of all keyboard actions
NC/PLC states are logged via the information channel status. At least in parts,
if they can be recorded by time, these statuses are used to verify the operation
of the MCP.
Logging of all movements between windows (current operating area, ID
number)
Logging of all modified NCK and PLC values,
for example, modified access to geometric data, such as tool offset and zero
offset
Logging of all PI services, which affect the NC-program workflow, for example,
Program selection, Delete file, Delete tool, etc.